TECHNICAL RESOURCES

Technical terms for coating measurement and testing

Document overview

The meaning of a technical value cannot be separated from its unit and measurement conditions. Film thickness in microns, pressure in bar, and surface roughness expressed as Ra describe different properties. Knowing which process stage a number refers to when reading a quotation or test report prevents comparisons between unlike data.

Units and surface measurements

A micron, or micrometer, is one millionth of a meter; 1 micron equals 0.001 millimeters. This unit, used for coating thickness, does not establish a common target range for every system. The required thickness is determined by the material and application conditions.

Bar is a unit of pressure. Read pressure in a blasting or spraying record together with the measurement location. Compressor outlet pressure and operating conditions near the spray gun must not be treated as the same data. Ra is a measure of surface roughness; a single average does not describe every peak and valley on the surface.

Film and temperature terms

TermDistinction to note when reading
Wet filmThe layer assessed after application, before drying is complete
Dry filmThe coating after the relevant drying or heat treatment
Oven settingThe temperature target entered in the control system
Part temperatureThe equipment’s measured thermal condition during processing
Holding timeTime spent under a defined condition

A curing profile describes the heating, holding, and cooling stages together. Recording only the peak temperature does not show the entire profile. Curing conditions and the permitted operating temperature in production may be based on different documents.

Testing and acceptance terminology

The test method defines how a measurement is made; the acceptance criterion defines which result is considered acceptable. Listing a standard code does not show that a sample passed the test. Measurement uncertainty and repetitions also matter, especially when interpreting results that are close to one another.

Calibration assesses the relationship between a measuring instrument and a reference; simply having an instrument or a digital display is not enough. Hardness can be measured by different methods, and values on different scales must not be converted directly into one another. When sending a technical information request to Powerpan, share the section of the report or specification containing the term. This makes it possible to clarify the measured property, method, and use context before focusing on the number.

Share this document:

Contact us for a project quotation